A Pre-Annual Meeting Course @ the SNAME 2011 Annual Meeting & Expo, November 16-18, 2011

Introduction:
The course will enable participants to obtain good knowledge of the fire safety requirements of SOLAS and the MODU Code.
Specification:
Upon completion of the course, the participant should expect to have gained general knowledge about the IMO organization and SOLAS build-up, the content and applicability of the MODU Code vs SOLAS and knowledge about statutory fire safety requirements. The course will focus on structural fire protection (fire categories, A- and B- class divisions, penetrations (doors, cables, pipes etc), arrangement of ventilation), selected fixed fire extinguishing systems (CO2, inside air foam, local application systems) and engine room fire safety. At last, Offshore Supply Vessels are used to exemplify fire safety precautions that apply for vessels undertaking special services (firefighting, oil recovery, standby, well stimulation etc).
Fee: $250.00 USD
Date: November 15, 2011
Time: 8:30 am - 5:00 pm
*Fees include breakfast, lunch, coffee, etc.
For registration related questions, please contact Cynthia.Ervin@dnv.com
Program
| Time | Agenda |
| 8:30 am -9:00 am | Registration and Breakfast |
| 9:00 am - 10:00 am | Welcome and Introduction IMO and SOLAS basics |
| 10:00 am - 10:10 am | Break |
| 10:10 am - 11:00 am | SOLAS vs MODU code Structural Fire Protection |
| 11:00 am - 11:10 am | Break |
| 11:10 am - 12:00 pm | Structural Fire Protection (continued) |
| 12:00 pm - 1:00 pm | Lunch |
| 1:00 pm - 2:00 pm | Fixed Fire Extinguishing Systems |
| 2:00 pm - 2:10 pm | Break |
| 2:10 pm - 3:00 pm | Engine Room Fire Safety |
| 3:00 pm - 3:10 pm | Break |
| 3:10 pm - 4:00 pm | Fire Safety on Offshore Supply Vessels |
| 4:00 pm - 4:10 pm | Break |
| 4:10 pm - 5:00 pm | Q&A and Close |
Lead Trainer: Kathrine Nerland
Kathrine Ilje Nerland (M.Sc.) joined DNV Houston Approval Center in 2010. She has been with DNV since 2003, mainly connected to the Fire Safety and Life-Saving section at Hovik, Norway. In 2005-2006 she worked as systems approval engineer at the Approval Centre East Asia in South-Korea. Before joining DNV she worked 3 years at a fire test laboratory in The Netherlands and 3 years as a consulting engineer in Oslo.
Ms. Nerland has experience from design approval of fire safety for cargo ships and mobile offshore units with respect to i.a. SOLAS, MODU Code, DNV Ship Rules, DNV Offshore Standards and Flag State requirements. This covers approval of both active and passive fire protection; e.g. location of spaces, materials, fire detection and alarm systems, structural protection, HVAC, escape, fire main, deluge, sprinkler and water mist systems, foam systems, CO2 and other equivalent gas fire extinguishing systems. She has also got experience from DNV type approval and MED approval of constructions, components and systems with respect to active and passive fire safety.